Medium Voltage Unarmoured Cable: Applications, Installation, and Selection Guide
Medium voltage unarmoured cable is a power cable without a protective metal armour layer, intended for medium voltage distribution where the route already provides suitable mechanical protection. Buyers commonly consider it for substations, industrial facilities, utility networks, and cable routes in ducts or controlled areas. To select it safely, match the voltage rating, conductor, insulation, screen, sheath, installation environment, and applicable project standard. At Zhongdong Cable Co., Ltd., we recommend confirming the complete cable specification and installation conditions before requesting a quotation.
Click here to get more.
Key Takeaways
- Unarmoured describes the lack of a dedicated armour layer; it does not mean that the cable has no insulation, metallic screen, or outer sheath.
- These cables are most suitable when the installation method protects them from likely impact, crushing, and other mechanical damage.
- Voltage class, conductor size and material, insulation, screen design, and sheath requirements should be confirmed together.
- Installation instructions and permissible bending or pulling limits must come from the selected cable design and project requirements.
Who This Guide Is For
This guide is for electrical contractors, EPC companies, utility and industrial procurement teams, distributors, and project engineers evaluating medium voltage cable. It is intended to support early product selection and supplier discussions, not to replace an engineered cable schedule or installation method statement. Requirements can differ by country, governing standard, network design, and site conditions. Confirm the applicable requirements with the project engineer before placing an order.
What Is Medium Voltage Unarmoured Cable?
A medium voltage unarmoured cable carries electrical power at a specified medium voltage and has no armour layer, such as steel wire or steel tape, around its cable core. A typical design may include a conductor, insulation system, semiconductive layers, a metallic screen, and an outer sheath. The precise construction varies by voltage rating, standard, manufacturer, and application. “Unarmoured” should therefore be treated as one design feature, not a complete description of the cable.
How the Main Components Work
The conductor carries current and is generally specified as copper or aluminium, subject to the electrical and project requirements. The insulation system separates the conductor from other conductive parts, while semiconductive layers may be used as part of the electric-field control design. A metallic screen provides a defined electrical path for fault current and grounding arrangements, as specified by the network design. The outer sheath protects the cable from environmental exposure appropriate to its declared construction, but it is not a substitute for armour where impact protection is required.
Voltage Ratings, Materials, and Specifications
Medium voltage cable ratings are stated as pairs that describe the rated voltage between conductor and earth and between conductors. Common examples include 6/10 kV, 12/20 kV, and 18/30 kV; these are examples, not a recommendation for any particular project. Select the rating using the network voltage, earthing arrangement, system conditions, and the governing standard. The exact voltage designation and construction must be stated in the purchase specification.
Specification Items to Confirm
| Specification | What the Buyer Should Confirm |
|---|---|
| Conductor | Copper or aluminium, cross-sectional area, conductor class, and any project-specific requirements. |
| Insulation | Material, rated voltage, applicable standard, and declared operating limits. Many XLPE cable designs specify a maximum conductor temperature of 90°C under normal operating conditions; verify this against the exact product and standard. |
| Metallic screen | Screen material and construction, cross-section, and compatibility with the project’s fault-current and earthing calculations. |
| Outer sheath | Material, colour if required, environmental suitability, and any specified resistance to moisture, sunlight, or chemicals. |
| Testing and documentation | Applicable standard, routine test documentation, marking, packaging, and required inspection records. |
Applications and Route Matching
Unarmoured medium voltage cable can suit substations, industrial plants, commercial infrastructure, and utility distribution routes when the cable is installed in a suitably protected environment. Common route types may include enclosed cable trenches, ducts, conduits, and designated indoor cable systems. The decision depends on the route’s mechanical risk, environmental exposure, access for maintenance, and local installation rules. Confirm that the complete cable design—not just the absence of armour—is suitable for the intended route.
When to Consider Another Construction
Where a cable could be exposed to vehicle traffic, excavation, impact, crushing, or other significant mechanical hazards, the project may require a mechanically protected route or a cable construction with armour. Direct burial should not be assumed to be suitable simply because the cable has an outer sheath. Check the manufacturer’s declared application and the project requirements before selecting direct burial or an exposed installation. If mechanical protection is provided separately, document its design and coverage as part of the installation plan.
Zhongdong Cable Co., Ltd. contains other products and information you need, so please check it out.
Installation Considerations
Safe installation begins with an approved route plan, a reviewed cable schedule, and the correct accessories for the cable construction. Before pulling, inspect the cable drum and sheath for visible damage, verify cable identification, and confirm that the pulling equipment and route are appropriate. Use the manufacturer’s instructions for minimum bending radius, pulling tension, sidewall pressure, and handling. These limits are product-specific, so do not apply a generic value without checking the cable data sheet.
Practical Installation Sequence
- Review the design: Confirm voltage, cable size, route length, termination locations, grounding, and the applicable installation standard.
- Prepare the route: Check ducts, trays, trench conditions, bends, access points, and protection from sharp edges or foreseeable mechanical damage.
- Plan the pull: Follow the cable manufacturer’s limits and use suitable rollers, pulling equipment, and approved pulling accessories.
- Install and identify: Handle the cable without damaging the sheath, maintain required separation and support, and label both ends as specified.
- Inspect and test: Complete inspections and electrical tests required by the project and applicable standard before energization.
Medium voltage termination and jointing require trained personnel and accessories matched to the cable’s insulation, screen, and conductor. Poor preparation or incorrect screen bonding can undermine the integrity of the installation. Coordinate cable delivery, jointing materials, and installation work so that the correct components are available together. Record test and inspection results in the project handover documentation.
A Buyer’s Selection Framework
1. Define Electrical and Environmental Requirements
Start with the system voltage, load, installation method, fault-current conditions, earthing arrangement, and environmental exposure. Provide the project standard and destination market because terminology and compliance requirements may vary. Include route details such as duct installation, trenching, indoor use, or outdoor exposure. This information helps a supplier assess whether an unarmoured construction is appropriate or whether additional protection should be considered.
2. Freeze the Cable Construction
Specify conductor material and size, insulation type, screen design, sheath material, and required cable length. Identify whether the cable will be installed as a single-core or multicore design, where relevant to the project. State any special requirements for marking, drum length, packaging, inspection, and documentation. Resolve these details before comparing quotations so that suppliers are pricing a consistent scope.
3. Compare Supplier Responses
Ask suppliers to provide a clear data sheet, construction details, applicable standards, available test documentation, and a list of deviations from the requested specification. Check whether the quotation identifies the exact voltage rating, conductor, screen, sheath, and delivery scope. Request clarification where the offer uses broad wording such as “standard cable” without defining the construction. A technically complete quotation is easier to evaluate than a low price based on assumptions.
Pricing, MOQ, and Lead Time
Pricing depends on factors such as conductor material and size, voltage rating, insulation and sheath materials, screen construction, order quantity, and requested documentation. Minimum order quantity and lead time can vary with the product configuration, production schedule, and available raw materials. We recommend requesting a project-specific quotation rather than relying on a generic price indication. Include the required quantity, delivery destination, preferred drum lengths, target delivery date, and complete technical specification.
Supplier Evaluation Checklist
- Can the supplier confirm the proposed cable construction against the project specification?
- Are the voltage designation, conductor, insulation, screen, and sheath clearly identified?
- Can the supplier state which standards and documents apply to the offered product?
- Are quotation assumptions, exclusions, packaging, drum lengths, and delivery terms explicit?
- Can the supplier support technical clarification before order confirmation and shipment?
Conclusion and Next Steps
Medium voltage unarmoured cable is a suitable option when its electrical design meets the network requirements and the installation route provides adequate mechanical protection. Select it by matching the voltage rating, conductor, insulation, metallic screen, sheath, installation environment, and governing standard—not by voltage alone. Before procurement, confirm installation limits with the product documentation and resolve any uncertainty about mechanical protection with the project engineer. Zhongdong Cable Co., Ltd. can review your required construction and quotation details; send us the voltage rating, cable specification, quantity, destination, and target delivery schedule to begin a B2B inquiry.